Encapsulated Calcium Sulphate Raised Access Floor is constructed using panels made of high density calcium sulphate, a mineral that provides stability and fire resistance. These panels are encapsulated in galvanized steel sheets.
Encapsulated Calcium Sulphate Raised Access Floor is well-known for its exceptional fire resistance and acoustic performance, making it a safe and noise-reducing option for a variety of commercial applications. Its modular design provides flexibility in configuration and customization, ensuring that it can meet the specific needs of a building's layout and design.
Calcium Sulphate Raised Floor Details. These panels consist of a flat calcium sulphate top sheet which is welded to a formed calcium sulphate bottom sheet.
Calcium Sulphate Raised Floor Characteristics
Load Capacity
Encapsulated calcium sulphate raised access floor has a high load-bearing capacity, typically ranging from 1,500 kg/m² to 3,000 kg/m². This makes it suitable for accommodating heavy office furniture, equipment, and foot traffic.
Good decoration
Various types of finishes can be added to the raised floor.
Enhanced durability
The encapsulated calcium sulphate raised access floor is highly durable and can withstand heavy loads and foot traffic, making it ideal for commercial office buildings with high daily footfall.
Fireproof Ability
The calcium sulphate material used in the flooring is inherently fire-resistant. In the event of a fire, it helps to delay the spread of flames and smoke, providing additional time for occupants to evacuate the building safely.
Sound Insulation performance
The encapsulated calcium sulphate raised access floor enhances acoustic performance by minimizing noise transmission between floors while providing superior sound insulation. This feature proves valuable in maintaining privacy/confidentiality or creating a peaceful work environment within commercial buildings.
Calcium Sulphate Raised Floor Specifications
When choosing raised floor, it's crucial for you to consider the specifications as they represent the performance of a typical installation. While Raised Access Floor Panel criteria, such as concentrated load, are often used to specify floor systems, this test isn't an accurate representation of an actual installation. It's performed with panel testing blocks, not actual understructure. Therefore, it's important to take into account all factors that may affect the performance of the Raised Access Floor System.
System Performance Criteria
Raised Floor
Static Loads
Rolling Loads
Type
Concentrated Load
Safety Factor (min.2.0)
Ultimated load
Uniform Load
10 Passes
10,000 Passes
ECS800
368kg/800lbs
Pass
736kg/1600lbs
1650kg/m2
318kg 700lbs
275kg 600lbs
PEC1000
454kg/1000lbs
Pass
909kg/2000lbs
2300kg/m2
368kg 800lbs
318kg 700lbs
PEC1250
568kg/1250lbs
Pass
1136kg/2500lbs
3300kg/m2
454kg 1000lbs
368kg 800lbs
Raised Access Floor design load is tested using CISCA Concentrated Load test method on actual understructure instead of steel blocks. The design load is determined by taking the lesser value of the ultimate load divided by two or the point at which permanent damage occurs (yield point).
The Raised Access Floor safety factor is the multiple of Design load to the Ultimate Load. International standards and Dawn recommend' a minimum of 2.
Calcium Sulphate Raised Floor Accessories
Finishes
Raised floors are widely used in office buildings, data centers, clean rooms and other places. Office buildings mainly use bare finish raised floor, the floor surface needs to be covered with carpet tiles. Data centers need to use anti-static flooring, the floor surface can use different types of anti-static coverings, such as anti-static laminate, PVC tile, ceramic tile and so on.
2201-1
2202
2103
2203
2206
2207
2208
2204
Installation accessories
The specifications of pedestals and stringers for different types of flooring are different. Please contact us if you need suggestion.
Low-Profile CS Pedestal
Standard CS Pedestal (OD25x1.5mm tube)
Standard CS Pedestal (OD22.3x1.5mm tube)
Standard CS Stringer
Other accessories
Grommets, outlet boxes, and electronic sockets can be used to facilitate wiring and routing. In some areas, we can use glass raised floor to monitor the situation under the raised floor.
Calcium Sulphate Raised Floor Production Line
Packing & Delivery
Steel Raised Floor Details. These panels consist of a flat steel top sheet which is welded to a formed steel bottom sheet.
A Yes, of course. Encapsulated Calcium Sulphate Raised Access Floor can be customized to fit specific project requirements. This includes customized panel sizes, finishes, and accessories, such as ramps, steps, and handrails.
A Encapsulated Calcium Sulphate Raised Access Floor has high load capacity and fireproof ability. It can reduce noise and contribute to sustainability. It also easy to be adapted or removed.