joeyzhao963@gmail.com        +86-18915016357
You are here: Home » Raised Access Floor » Steel Concrete Raised Access Floor » Conductive Steel Concrete Raised Floor with PVC Finish

Conductive Steel Concrete Raised Floor with PVC Finish

Conductive Steel Concrete Raised Floor with PVC Finish is a specialized type of flooring system designed to prevent the buildup of static electricity, making it ideal for use in areas having sensitive electronic equipment. This flooring is made up of high-quality steel panels, covered with a conductive PVC layer, which provides exceptional durability and strength. The conductive properties of this flooring aid in the dissipation of electrical charges and provide an additional layer of protection for electronic equipment. It is commonly used in data centers, laboratories, and other areas where electrostatic discharge is a concern.

    Type

   FS700, FS800, FS1000, FS1250

    Size

   600*600*35mm

    Materials

   steel, cement

    Installation

   stringer system

    Finish

   PVC

    Edging    Fold edging / Cut edging

Steel Concrete Raised Floor Video

Steel Raised Floor Details. These panels consist of a flat steel top sheet which is welded to a formed steel bottom sheet.

Steel Concrete Raised Floor Characteristics

Excellent load performance
Class A flame spread & smoke developed index.
Good decoration
anti-pilling-fabric
 
 
Electrostatic Discharge Protection
 
Anti-static raised access flooring with HPL finish prevents the buildup of static electricity, which can damage sensitive electronic equipment in data centers. This helps to protect the data center's equipment from electrostatic discharge (ESD).
non-toxic
 
 
Chemical Resistance
 
The PVC covering of conductive steel PVC raised access floor provides excellent chemical resistance, making it resistant to many common chemicals found in data centers.
  
   
Frame 6356056
 
 
Enhanced durability
 
The combination of steel and PVC materials in conductive steel PVC raised access flooring provides excellent durability and long-term performance, even in high-traffic areas.
  
  

Steel Concrete Raised Floor Specifications

When choosing raised floor, it's crucial for you to consider the specifications as they represent the performance of a typical installation. While Raised Access Floor Panel criteria, such as concentrated load, are often used to specify floor systems, this test isn't an accurate representation of an actual installation. It's performed with panel testing blocks, not actual understructure. Therefore, it's important to take into account all factors that may affect the performance of the Raised Access Floor System.
System Performance Criteria
Raised Floor Static Loads Rolling Loads
Type Size Concentrated
Load
Safety Factor
(min.2.0)
Ultimated load 10 Passes 10,000 Passes
FS800 600x600x35mm
610x610x35mm
 368kg/800lbs Pass 736kg/1600lbs 318kg
700lbs
275kg
600lbs
FS1000 600x600x35mm
610x610x35mm
454kg/1000lbs Pass 909kg/2000lbs 368kg
800lbs
318kg
700lbs
FS1250 600x600x35mm
610x610x35mm
568kg/1250lbs Pass 1136kg/2500lbs 454kg
1000lbs
368kg
800lbs
FS1500 600x600x35mm
610x610x35mm
681kg/1250lbs Pass 1363kg/3000lbs 568kg
1250lbs
454g
1000lbs
FS2000 600x600x35mm
610x610x35mm
909kg/1250lbs Pass 1818kg/4000lbs 681kg
1500lbs
568kg
1250lbs
FS2500 600x600x35mm
610x610x35mm
1136kg/1250lbs Pass 2272kg/5000lbs 909kg
2000lbs
681kg
1500lbs
FS3000 600x600x35mm
610x610x35mm
1363kg/1250lbs Pass 2726kg/6000lbs 1136kg
2500lbs
909kg
2000lbs
 Raised Access Floor design load is tested using CISCA Concentrated Load test method on actual understructure instead of steel blocks. The design load is determined by taking the lesser value of the ultimate load divided by two or the point at which permanent damage occurs (yield point).
The Raised Access Floor safety factor is the multiple of Design load to the Ultimate Load. International standards and Dawn recommend' a minimum of 2.

Steel Concrete Raised Floor Accessories

  Conductive PVC Finishes
Conductive PVC finish can provide electrical conductivity to PVC surfaces. This can be crucial in applications where static electricity needs to be dissipated or where conductivity is required for specific electronic or industrial purposes.
  Installation accessories
The finished access floor will be rigid, free from vibration and rocking panels within a 3mm level over the entire space. Panels will be accurately cut to fit around all permanent features. All whole panels will be completely interchangeable allowing for any future changes. The access floor will maintain these original conditions when sufficient panels have been removed for normal underfloor access.

Pedestals and stringers are necessary for installation. The specifications of pedestals and stringers for different types of flooring are different. Please contact us if you need suggestion.
  Other accessories
Grommets, outlet boxes, and electronic sockets can be used to facilitate wiring and routing. In some areas, we can use glass raised floor to monitor the situation under the raised floor.

Steel Concrete Raised Floor Production Line

Packing & Delivery

Steel Raised Floor Details. These panels consist of a flat steel top sheet which is welded to a formed steel bottom sheet.
package (3)
 
 
 
Packing Details
 
Wooden pallets
 
delivery (2)
 
 
 
Delivery Details
 
15-20 days
 

Conductive Steel PVC Concrete Raised Floor FAQ

Related Products

Contact HUILIAN Support Team

*Please feel free to contact us. Our sales team will follow you as soon as possible.
Contact us
Expert Raised Floor Manufacturer  |  20+ years Experience
Professional R&D and Quality Inspection Team  |   Wide Range of Products
Products
Why HUILIAN
Case
© COPYRIGHT 2024 JIANGSU HUILIAN ACTIVITY FLOORING CO., LTD. ALL RIGHTS RESERVED.